System:configure:current:control, System:configure:voltage:control – GW Instek PSW-Series Programming & Command manual User Manual

Page 81

Advertising
background image

REMOTE CONTROL

81

ON

Enables the power switch trip for OVP or
OCP.

Return parameter <Boolean>

Returns power switch trip setting.

SYSTem:CONFigure:CURRent:CONTrol

Set

Query

Description

Sets or queries the CC control mode (local control
(panel), external voltage control, external
resistance control). This setting is applied only
after the unit is reset.

Syntax
Query Syntax

SYSTem:CONFigure:CURRent:CONTrol { 0 | 1 | 2 | 3 }
SYSTem:CONFigure:CURRent:CONTrol?

Parameter/Return <NR1>

Description

0

Local (Panel) control

1

External voltage control

2

External resistance control; 10kΩ = Io max,
0kΩ = Io min.

3

External resistance control; 10kΩ = Io min,
0kΩ = Io max.

SYSTem:CONFigure:VOLTage:CONTrol

Set

Query

Description

Sets or queries the CV control mode (local control,
external voltage control, external resistance
control). This setting is applied only after the unit
is reset.

Syntax
Query Syntax

SYSTem:CONFigure:VOLTage:CONTrol { 0 | 1 | 2 | 3 }
SYSTem:CONFigure:VOLTage:CONTrol?

Parameter/Return <NR1>

Description

0

Local (Panel) control

1

External voltage control

2

External resistance control; 10kΩ = Vo max,
0kΩ = Vo min.

3

External resistance control; 10kΩ = Vo min,
0kΩ = Vo max.