57

Example

DISP:MENU:NAME 0
Sets the display to the Voltage/Current display screen.

DISPlay[:WINDow]:TEXT:CLEar

Set

Description

Clears the text on the main screen from the
DISPlay[:WINDow]:TEXT[:DATA] command .

Syntax

DISPlay[:WINDow]:TEXT:CLEar

DISPlay[:WINDow]:TEXT[:DATA]

Set

Query

Description

Sets or queries the data text that will be written to
the display. Writing to the display will overwrite
data that is currently on the screen. Overwriting a
display area with a shorter string may or may not
overwrite the screen. The string must be enclosed
in quotes: “STRING”. Only ASCII characters 20H
to 7EH can be used in the <string>.

Syntax
Query Syntax

DISPlay[:WINDow]:TEXT[:DATA] <string>
DISPlay[:WINDow]:TEXT[:DATA]?

Parameter/
Return parameter

<string>

ASCII character 20H to 7EH can be used to in
the string parameter. The string must be
enclosed in quotes: “STRING”

Example

DISP:WIND:TEXT:DATA “STRING”
Writes STRING to the display.

Query Example

DISP:WIND:TEXT:DATA?
“STRING”
Returns the text data string on the screen.

DISPlay:BLINk

Set

Query

Description

Turns blink on or off for the display.

Syntax
Query Syntax

DISPlay:BLINk { 0 | 1 | OFF | ON }
DISPlay:BLINk?