Output:protection:clear, Output:protection:tripped – GW Instek PSW-Series Programming & Command manual User Manual

Page 62

Advertising
background image

PSW Series Programming Manual

62

Parameter

0

<NR1>Turns the output off when a software
trigger is generated.

OFF

Turns the output off when a software trigger
is generated.

1

<NR1>Turns the output on when a software
trigger is generated.

ON

Turns the output on when a software trigger
is generated.

Return parameter <NR1>

Returns output trigger status of the
instrument.

OUTPut:PROTection:CLEar

Set

Description

Clears over-voltage, over-current and over-
temperature (OVP, OCP, OTP) protection circuits.
It also clears the shutdown protection circuit. The
AC failure protection cannot be cleared.

Syntax

OUTPut:PROTection:CLEar

OUTPut:PROTection:TRIPped

Query

Description

Returns the state of the protection circuits (OVP,
OCP, OTP).

Query Syntax

OUTPut:PROTection:TRIPped?

Return parameter 0

<NR1>Protection circuits are not tripped.

1

<NR1>Protection circuits are tripped.

Advertising