Usb remote control function check – GW Instek PSW-Series Programming & Command manual User Manual

Page 34

Advertising
background image

PSW Series Programming Manual

34

F-44 = 255

Subnet Mask part 2 of 4

F-45 = 128

Subnet Mask part 3 of 4

F-46 = 0

Subnet Mask part 4 of 4

F-43 = 172

Gateway part 1 of 4

F-44 = 16

Gateway part 2 of 4

F-45 = 21

Gateway part 3 of 4

F-46 = 101

Gateway part 4 of 4

F-57 = 1

Enable Sockets

Note

The socket function is only available for firmware
version V1.12 or above. See the user manual to
check your firmware version number.

USB Remote Control Function Check

Functionality
check

Invoke a terminal application such as Realterm.
The PSW will appear as a COM port on the PC.

To check the COM port No, see the Device
Manager in the PC. For WinXP; Control panel
→ System → Hardware tab.

Note

If you are not familiar with using a terminal
application to send/receive remote commands via
a USB connection, please page 35(Using Realterm
to Establish a Remote Connection)
for more
information.

Run this query command via the terminal after
the instrument has been configured for USB
remote control (page 30).
*idn?
This should return the Manufacturer, Model
number, Serial number, and Firmware version
in the following format.

GW-INSTEK,PSW-XXX-X,TW123456,01.00.20110101

Advertising