Trigger:output[:immediate, Trigger:output:source, Trigger command examples – GW Instek PSW-Series Programming & Command manual User Manual

Page 76

Advertising
background image

PSW Series Programming Manual

76

TRIGger:OUTPut[:IMMediate]

Set

Description

Generates a software trigger for the output trigger
system. On a trigger, sets the output state. Refer to
the :OUTP:TRIG command on page 61.

Syntax

TRIGger:OUTPut[:IMMediate]

Related
commands

OUTPut[:STATe]:TRIGgered

TRIGger:OUTPut:SOURce

Set

Query

Description

Sets or queries the trigger source for the output
system.

Syntax

TRIGger:OUTPut:SOURce [BUS | IMMediate]

Query Syntax

TRIGger:OUTPut:SOURce?

Parameter/Return BUS

Internal software trigger. Waits for the
*TRG (or IEEE 488.1 “get” group
execute trigger) command to start the
trigger.

IMMediate

Starts the trigger immediately.
(default)

Example

TRIG:OUTP:SOUR BUS
Sets the trigger source of the output system as BUS.

Trigger Command Examples

1. The transient system for the trigger in immediate mode.

Example 1

TRIG:TRAN:SOUR IMM
CURR:TRIG MAX
VOLT:TRIG 5

INIT:NAME TRAN

<==The current changes to the
maximum, and the voltage
changes to 5V.

Advertising