REMOTE CONTROL

73

[SOURce:]VOLTage[:LEVel]:TRIGgered
[:AMPLitude]

Set

Query

Description

Sets or queries the voltage level in volts when a
software trigger has been generated.

Syntax

[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]
{<NRf>|MIN|MAX}

Query Syntax

[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]?
[MIN|MAX]

Parameter/Return <NRf>

0%~105% of the rated voltage output in volts.

MIN

Minimum current level.

MAX

Maximum current level.

Example

SOUR:VOLT:LEV:TRIG:AMPL 10
Sets the voltage level to 10 volts when a software
trigger is generated.

[SOURce:]VOLTage:PROTection[:LEVel]

Set

Query

Description

Sets or queries the overvoltage protection level.

Syntax

[SOURce:]VOLTage:PROTection[:LEVel]
{<NRf>|MIN|MAX}

Query Syntax

[SOURce:]VOLTage:PROTection[:LEVel]? [MIN|MAX]

Parameter/Return <NRf>

OVP range in volts.

MIN

Minimum OVP level

MAX

Maximum OVP level

Example

SOUR:VOLT:PROT:LEV MAX
Sets the OVP level to its maximum.

[SOURce:]VOLTage:SLEW:RISing

Set

Query

Description

Sets or queries the rising voltage slew rate. This is
only applicable for CV slew rate priority mode.