Output:mode, Output[:state][:immediate, Output[:state]:triggered – GW Instek PSW-Series Programming & Command manual User Manual

Page 61

Advertising
background image

REMOTE CONTROL

61

OUTPut:MODE

Set

Query

Description

Sets the PSW output mode. This is the equivalent
to the F-03 (V-I Mode Slew Rate Select) settings.

Syntax
Return Syntax

OUTPut:MODE {<NR1>|CVHS|CCHS|CVLS|CCLS}
OUTPut:MODE?

Parameter

0

CV high speed priority

CVHS

CV high speed priority

1

CC high speed priority

CCHS

CC high speed priority

2

CV slew rate priority

CVLS

CV slew rate priority

3

CC slew rate priority

CCLS

CC slew rate priority

Return parameter <NR1>

Returns the output mode.

OUTPut[:STATe][:IMMediate]

Set

Query

Description

Turns the output on or off.

Syntax
Query Syntax

OUTPut[:STATe][:IMMediate] { OFF | ON | 0 | 1 }
OUTPut[:STATe][:IMMediate]?

Parameter

0

<NR1> Turns the output off.

OFF

Turns the output off.

1

<NR1> Turns the output on.

ON

Turns the output on.

Return parameter <NR1>

Returns output status of the instrument.

OUTPut[:STATe]:TRIGgered

Set

Query

Description

Turns the output on or off when a software trigger
is generated.

Syntax
Query Syntax

OUTPut[:STATe]:TRIGgered { OFF | ON | 0 | 1 }
OUTPut[:STATe]:TRIGgered?