Sense commands, Sense:average:count – GW Instek PSW-Series Programming & Command manual User Manual

Page 63

Advertising
background image

REMOTE CONTROL

63

Sense Commands

SENSe:AVERage:COUNt ................................................... 63

SENSe:AVERage:COUNt

Set

Query

Description

Determines the level of smoothing for the average
setting. This is the equivalent to the F-17 function
setting.

Syntax

Query Syntax

SENSe:AVERage:COUNt {<NR1>| LOW | MIDDle |
HIGH}
SENSe:AVERage:COUNt?

Parameter

0 | LOW

Low level of smoothing.

1 | MIDDle

Middle level of smoothing.

2 | HIGH

High level of smoothing.

Return parameter <NR1>

Returns the level of smoothing.

0

Low level of smoothing.

1

Middle level of smoothing.

2

High level of smoothing.

Example

SENSe:AVERage:COUNt 1
Sets the level of smoothing to middle.

Advertising