Source:]current[:level]:triggered [:amplitude, Source:]current:protection[:level – GW Instek PSW-Series Programming & Command manual User Manual

Page 69

Advertising
background image

REMOTE CONTROL

69

[SOURce:]CURRent[:LEVel]:TRIGgered
[:AMPLitude]

Set

Query

Description

Sets or queries the current level in amps when a
software trigger has been generated.

Syntax

[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]
{<NRf>|MIN|MAX}

Query Syntax

[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]?
[MIN|MAX]

Parameter/Return <NRf>

0%~105% of the rated current output in amps.

MIN

Minimum current level.

MAX

Maximum current level.

Example

SOUR:CURR:LEV:TRIG:AMPL? MAX
37.800
Returns the maximum possible current level in amps.

[SOURce:]CURRent:PROTection[:LEVel]

Set

Query

Description

Sets or queries the OCP (over-current protection)
level in amps.

Syntax

[SOURce:]CURRent:PROTection[:LEVel]
{<NRf>|MIN|MAX}

Query Syntax

[SOURce:]CURRent:PROTection[:LEVel]? [MIN|MAX]

Parameter/Return <NRf>

OCP range in Amps.

MIN

Minimum current level.

MAX

Maximum current level.

Example

SOUR:CURR:PROT:LEV? MIN
+3.600
Returns the minimum possible current level in amps.