Communication failure—site 2 to quorum witness – HP 3PAR Operating System Software User Manual

Page 147

Advertising
background image

Figure 57 Communication Failure—Site 2 to Quorum Witness

Communication Failure—Site 2 to Quorum Witness and Site 1 to Site 2

In a dual-network communication failure between site 2 and the quorum witness, and between site
1 and site 2 (see

Figure 58 (page 147)

):

HP 3PAR StoreServ array A reacts to the isolation of HP 3PAR StoreServ array B just as it
would react to a failure of HP 3PAR StoreServ array B. However, because HP 3PAR StoreServ
array A is already source, no action is required.

A failover does not happen:

Host I/O continues to go to source volumes.

Replication of I/O across remote-copy links stops.

Figure 58 Communication Failure—Site 2 to Quorum Witness and Site 1 to Site 2

HP 3PAR Peer Persistence Quorum

147