Table 15 Path status and examples of recovery procedures (Thunder 9500V subsystems) (continued)

Examples of recovery procedures

Path status

There is a problem with the connection to the external
array. The following are possible causes:

Cannot detect port

The fibre cable is not connected properly.

The topology setting between the external and target
ports does not match.

If the external array is connected through switches, the
switches' settings might not be appropriate.

Check if the fibre cable is connected properly, and use XP
LUN Configuration and Security Manager Software to set
the Fibre Channel port properly.

XP LUN Configuration and Security Manager Software
may have enabled host group security.

Check if host group security is enabled. If host group
security is enabled, disable host group security.

Connecting TagmaStore AMS and TagmaStore WMS subsystems

System parameters for connecting TagmaStore AMS and TagmaStore WMS
subsystems

Table 16 (page 145)

explains whether to specify system parameters when making settings for ports

on TagmaStore AMS and TagmaStore WMS subsystems.

NOTE:

When connecting to a TagmaStore AMS or TagmaStore WMS subsystem, use XP LUN

Configuration and Security Manager Software to set the data transfer speed of the
XP12000/XP10000/SVS200 external port you use to a fixed value other than Auto Negotiation.
Also, set the data transfer speed of the target port of the TagmaStore AMS or TagmaStore WMS
subsystem to the same fixed value according to the data transfer speed of the external port.

Table 16 System parameter settings (TagmaStore AMS and TagmaStore WMS subsystems)

Parameter setting

Parameters

Pane name

Start Attribute

Boot Options

Specify this parameter when the
TagmaStore AMS or TagmaStore WMS

Single Mode

subsystem is in the one-controller
configuration.

Specify this parameter when the
TagmaStore AMS or TagmaStore WMS

Dual Active Mode

subsystem is in the two-controller
configuration.

You can either specify this parameter
or omit specifying this parameter.

Delay Planned Shutdown

You can either specify this parameter
or omit specifying this parameter.

Drive blocking mode

Keep this parameter as HITACHI
(default), and do not change.

Vendor ID

Keep this parameter as DF600F
(default), and do not change.

Product ID

You can either specify this parameter
or omit specifying this parameter.

ROM Microprogram Version

Connecting TagmaStore AMS and TagmaStore WMS subsystems