Table 19 Path status and examples of recovery procedure (TagmaStore AMS and TagmaStore WMS
subsystems)

Examples of recovery procedures

Path status

XP LUN Configuration and Security Manager Software
may have changed the LU paths' settings.

External device setting changed

Check the LU paths' settings. If the LU paths' settings
changed, change the settings back to the ones used when
the volume was mapped. Or use XP External Storage to
perform the Delete LU operation, and perform the Add LU
operation again.

XP LUN Security Extension may have changed the volume's
access attribute.

Check the volume's access attribute. If the volume is
protected by the access attribute, release the protection.

The volume may have been set as a pair volume for data
copy.

Illegal request

Check if the volume is set as a pair volume for XP Business
Copy, XP Continuous Access, or another copy program.
If the volume is set as a pair volume, the volume might be
protected because of the pair status. If the volume is
protected, change the pair status or delete the pair.

XP LUN Security Extension may have changed the volume's
access attribute.

Check the volume's access attribute. If the volume is
protected by the access attribute, release the protection.

The volume may have been set as a pair volume for data
copy.

Response error

Check if the volume is set as a pair volume for XP Business
Copy, XP Continuous Access, or another copy program.
If the volume is set as a pair volume, the volume might be
protected because of the pair status. If the volume is
protected, change the pair status or delete the pair.

XP LUN Security Extension may have changed the volume's
access attribute.

Check the volume's access attribute. If the volume is
protected by the access attribute, release the protection.

There is a problem with the connection to the external
array. The following are possible causes:

Cannot detect port

The fibre cable is not connected properly.

The topology setting between the external and target
ports does not match.

If the external array is connected through switches, the
switches' settings might not be appropriate.

Check if the fibre cable is connected properly, and use XP
LUN Configuration and Security Manager Software to set
the Fibre Channel port properly.

XP LUN Configuration and Security Manager Software
may have enabled the host group security.

Check if host group security is enabled. If host group
security is enabled, disable host group security.

148

Notes on connecting external arrays