Allied Telesis AT-S63 User Manual
Page 76
Chapter 2: Port Parameters
76
Section I: Basic Operations
b. If you enabled the feature, type 2 to select Unknown Unicast Rate.
The following prompt is displayed:
Enter the Rate Limit (packets/second):[0 to 262143]->
c. Enter a number for the rate limit.
6. To control multicast packets, do the following:
a. Type 3 to toggle Multicast Rate Limiting Status between Enabled
and Disabled.
b. If you enabled the feature, type 4 to select Multicast Rate.
The following prompt is displayed:
Enter the Rate Limit (packets/second):[0 to 262143]->
c. Enter a number for the rate limit.
7. To control broadcast packets, do the following:
a. Type 5 to toggle Broadcast Rate Limiting Status between Enabled
and Disabled.
b. If you enabled the feature, type 6 to select Broadcast Rate.
The following prompt is displayed:
Enter the Rate Limit (packets/second):[0 to 262143]->
c. Enter a number for the rate limit.
8. After making changes, type R until you return to the Main Menu. Then
type S to select Save Configuration Changes.