Application example: Flying saw

Error handling: Configuring the error handling

170

Lenze · ApplicationTemplate · 1.3 EN - 04/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Assign the variables to the AxisBasicControl block.

• Location:

Module application

MAP_B01_Infeed_App1\Action

S00_CYCLIC

• The variables must be interconnected to the xJoggingPos and xJoggingNeg inputs

of

AxisBasicControl.

• Assign the values for speed, acceleration, deceleration to the L_SMC_AxisBasicControl

function block:

The assignments for the variables must be positioned in front of the call of the block

instance. If the assignments are positioned behind, they will not be effective before the

subsequent cycle.

13.8

Error handling: Configuring the error handling

In this example, the enable of the axes must be monitored during a state change:

The error handling is supposed to trigger an error if the axes are not enabled within 200 ms.

• For this purpose, the axes must be inhibited via the hardware input.
• It should be possible to detect and control the error and the error response in the visualization.
• It should be possible to acknowledge the error via a button in the visualization.

The example below shows how the desired error response can be configured in the MM_B01_Infeed

machine module.

How to proceed:

1. Declare the variables in the Mvis_* structure.

Double-click and open:

A70_MachineModuleSources\ MM_B01_Infeed

• Structure

MVis_scB01_Infeed

In the structure, declare a variable of the BOOL data type for acknowledging the error,

example: xQuit.

2. Insert the buttons into the visualization.