Architecture: The ApplicationTemplate in detail

State machine

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.3

State machine

The machine module (which is on the highest level of the MachineModuleTree MMT) controls the

state machine of all lower-level machine modules.

• The resulting state transitions have an impact on the subordinated machine modules.

9.3.1

State transitions and conditions - overview

This section illustrates the individual state transitions of the ApplicationTemplate state machine.

For each state transition, the conditions required in each case are specified. The state transitions are

numbered and then described in the text:

Labelled with

State/identifier

Description

Initialisation

Init

Initialisation of the module / module application is always required.

• After a RESET, the "Init""Ready" state transition is inhibited.

• Then the "Init""Ready" state transition is to be enabled by the

module application (when initialisation has been completed).

• The SMEnableInitToReady(TRUE/FALSE) method enables /

inhibits the state transition.

Enable/inhibit mechanism

• ...permits the module applications to inhibit/enable the

respective state transition.

...

Idle state

Ready

Ready for operation. This is the basic state of the state machine.

Manual operation

Manual

Enable/inhibit mechanism

• In this state, the controller can be controlled in manual mode, for

instance for cleaning or changing the tool.

• By setting the individual control bits, the controller can be

controlled manually (Jog1, Jog2, QSP, ErrorReset...).

• This state permits the module applications to inhibit/enable the

underlying state transition.

Service

Service operation for maintenance purposes

MM_Module1: Load value (example: 123)

MM_Module2: Load value (example: 567)

Automatic

Automatic operation

MM_Module1: Incrementing (50 units per second)

MM_Module2: Incrementing (20 units per second)