_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.10.2

Frequently asked question: Connection between MFB and MAP

MFB_Module1 function block
The MachineModuleTree (MMT) maps the mechatronic structure of the automation system by

means of the MFB function blocks (MFB_Modulexx).

• Instancing of the MFB_Module1 must be executed in the

MM_Dcl structure of the

A55_VarLists folder.

• Insert the instance in the desired position of the MMT.

[8-3]

Example: Machine module tree in the ApplicationTemplateCounter

• A machine module encloses the module applications in the machine module.
• Therefore the module applications are to be declared within the machine module.

Instance the MAP_Module1_App1 module application with the following declaration line, so that

the instance can be called according to the task in the module application of ModuleAppCalls:

• The parentModule:= THIS^ instruction connects the App1 module application to the basic

functions of all machine modules (e.g. state machine, error handling, BaseChannel). That way,

the App1 module application can access the basic functions of the ApplicationTemplate.

• Assign the ACD structure manually.



The AppChannelData structure(ACD)

( 73)

[8-4]

Example: App1

App1: MAP_Module1_App1 := (parentModule := THIS^);