Architecture: The ApplicationTemplate in detail

Error handling

94

Lenze · ApplicationTemplate · 1.3 EN - 04/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2. Activation for one cycle: Via the baseChannelSetErrorQuit method, rising edge FALSE

Ê

TRUE. The

method sets the xQuitErrors input to TRUE for one cycle.

If multiple errors occur, they cannot be acknowledged individually. Further information:



L_EATP_ModuleErrorHandler

( 124)

9.9.4

Acknowledging errors: Response in the machine module

The xErrorQuitActive output on the L_EATP_ModuleErrorHandler block can be used within a module

application to acknowledge errors on an integrated function block.

Defining errors - standard procedure

ErrorHandler.xQuitErrors := TRUE; //error acknowledgement active as long as value =
TRUE

• The

SetErrors method is to be

extended by one function block.

• The MAP_EmptyModul_App1 FB is

to be extended by the

corresponding declaration.

• The xSetError[1...4] inputs must be

connected to the module

application.

• Assign the corresponding

parameter to the respective error

input:

• Error number,
• Error text,
• Error priority,
• Acknowledgement response

• More information:



L_EATP_ErrorSet

( 119)