Opening the ApplicationTemplate

Update the controller in the project (optional)

32

Lenze · ApplicationTemplate · 1.3 EN - 04/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2

Update the controller in the project (optional)

Cases in which the project must be updated
The controller in the »PLC Designer« must be updated if ...

• ...the project contains firmware information that is older than the hardware to be used or
• ...a controller other than the integrated 3200 C controller is desired (example: p500).

If the controller is marked with the

icon after the project is opened, the device information of

the »PLC Designer« project have to be updated.

Determining the firmware of the controller

How to proceed:

• Use the »WebConfig« to check which firmware is used by the controller to select the

appropriate device information in the »PLC Designer«.

• If the controller must be updated, the dynamic memory settings of the application must be

adapted.

Adapting the memory settings

Highlight the desired controller.

• Execute the Update device command in the context menu.
• Double-click the applicable controller in the Update device dialog window to update the

controller in the Device view:

1. In the context menu of

Application, execute the

Properties command.

• On the Application build options tab, activate the; Use dynamic memory allocation

option.

• For Maximum size of memory, enter a value of 100000:

• Click OK to confirm.