Lenze · ApplicationTemplate · 1.3 EN - 04/2013

53

Working with the ApplicationTemplate

Integrating a machine module into the MMT

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.3

Integrating a machine module into the MMT

The machine module (created on the basis of the MM_EmptyModule template) has to be integrated

into the MachineModuleTree(MMT) to implement it in the ApplicationTemplate in a serviceable

state.

How to proceed:

1. Double-click the

A10_MachineModuleTree folder in the device view.

Double-click MMT (PRG).

Note: The programming language of MMT (PRG) is CFC (Continuous Function Chart).

• In the Tools dialog window, click the

Block button.

• Create the new FB via drag-and-drop.

• Double-click the

area of the FB. Click the

button.

Use the Input assistance from the

Application element...

• ...to assign the MFB_CrossCutter FB.
• ...to assign the CrossCutter instance.

Note: Go to the Input assistant and select the ; Insert with namespace prefix when

assigning the instance name.

2. Specify the relative address for the machine module.

• In the Tools dialog window, click the

Input button.

• Add the new input at MM_Address
• Assign the relative address (example: 3).

3. Connect FBs MFB_MachineControl and MFB_CrossCutter to each other.

• Example (ApplicationTemplate Counter):

Note: After inserting a machine module, the processing order of the machine modules

which results after inserting the further machine module is to be checked.
For changing the Processing order, adapt the element number in the top right corner of

the corresponding machine module.

• For this, call the Processing order menu item in the context menu of the element