5–9 drive wiring – Rockwell Automation 1302 575v AC Drive - Canada Only User Manual
Page 45
Advertising
5–9
Drive Wiring
Publication 1302-5.0 — January, 1998
Figure 5.9
Snubber Resistor Wiring Connections for 1302 Drives
12 13
+ -
DC BUS
VOLTS
REGULATOR
BOARD
CONTROL
TERMINAL
STRIP
POWER
TERMINAL
STRIP
24 VDC COMMON
BRAKING SIGNAL
SNUBBER RESISTOR
SNUBBER RESISTOR
SNUBBER RESISTOR
BRAKING SIGNAL
DC BUS VOLTS
+1
-2
+147
-45
+ -
10V 10V
COM
10V SUPPLY
+13
-14
SP500 DRIVE
Output Status Relay Wiring
Output status wiring connects to terminals 14 through 16 on the
Regulator board’s terminal strip. See Figure 5.10. Parameter F-09
specifies the type of status indication provided by the output relay.
See the F-09 parameter description in Chapter 8 for more
information.
Figure 5.10
Output Status Relay Wiring Connections
14
15 16
N.O.
USERĆSUPPLIED
LAMP
USERĆSUPPLIED
115 VAC / 24 VDC
(10 mA Min.)
Advertising