5–9

Drive Wiring

Publication 1302-5.0 — January, 1998

Figure 5.9
Snubber Resistor Wiring Connections for 1302 Drives

12 13

+ -

DC BUS

VOLTS

REGULATOR

BOARD

CONTROL

TERMINAL

STRIP

POWER

TERMINAL

STRIP

24 VDC COMMON

BRAKING SIGNAL

SNUBBER RESISTOR

SNUBBER RESISTOR

SNUBBER RESISTOR

BRAKING SIGNAL

DC BUS VOLTS

+1

-2

+147

-45

+ -

10V 10V

COM

10V SUPPLY

+13

-14

SP500 DRIVE

Output Status Relay Wiring

Output status wiring connects to terminals 14 through 16 on the
Regulator board’s terminal strip. See Figure 5.10. Parameter F-09
specifies the type of status indication provided by the output relay.
See the F-09 parameter description in Chapter 8 for more
information.

Figure 5.10
Output Status Relay Wiring Connections

14

15 16

N.O.

USERĆSUPPLIED

LAMP

USERĆSUPPLIED

115 VAC / 24 VDC

(10 mA Min.)