Rockwell Automation 1302 575v AC Drive - Canada Only User Manual

Page 71

Advertising
background image

8–13

Programming

Publication 1302-5.0 — January, 1998

FĆ16 Coast Stop Enable

This parameter selects how the

motor will stop when given a

stop command.

Parameter Range:

Default Setting:

Step Size:

ON = Enable coast stop (motor will

coast to rest)

OFF = Disable coast stop (motor will

ramp to rest)

OFF

1%

!

ATTENTION: You must provide an external, hardwired emergency stop circuit outside of the

drive circuitry. This circuit must disable the system in case of improper operation. Uncontrolled

machine operation may result if this procedure is not followed. Failure to observe this

precaution could result Drive or equipment damage, bodily injury or death!

A coastĆtoĆrest stop turns off the transistor power device drivers. A rampĆtoĆrest stop fires the transistor

power device drivers until the motor comes to a stop and then turns off the power device drivers.

Note that the function loss input opening or a Drive fault will always cause a coastĆtoĆrest stop.

FĆ17 Reverse Disable

This parameter enables or

disables reverse rotation of the

motor.

Parameter Range:

Default Setting:

Step Size:

ON = Disable reverse

OFF = Enable reverse

OFF

N/A

If FĆ17 = OFF, the forward/reverse input allows forward or reverse rotation of the motor.

If FĆ17 = ON, reverse rotation of the motor is prohibited. When FĆ17 = ON, pressing the

Forward
Reverse

key on the

keypad in local control, or wiring to terminal 9 on the terminal strip in remote control, does not affect Drive

operation.