Program mode – Rockwell Automation 1302 575v AC Drive - Canada Only User Manual
Page 54
7–4
Display and Keypad Operation
Publication 1302-5.0 — January, 1998
Table 7.C - Monitor Mode LED Descriptions
LED
Corresponding Display When LED is On (Actual Value)
RPM/Engineering Unit
Motor speed in RPM or in a userĆspecified engineering unit. (Refer to the
FĆ08 parameter description for more information.)
%Load
Percentage of Drive full load amps rating.
Volts
Drive output voltage to the motor.
All LEDs (RPM, %Load, Volts) Value of the active speed reference signal as 0 to 100% of the total scaled
reference range. FĆ13 must be set to ON to display this value. (Refer to the
FĆ13 parameter description for more information.)
Program mode allows you to display and modify Drive parameter
values when the Drive is stopped. The following can be displayed in
program mode:
•
Parameter numbers
•
Parameter values
•
Error log information
To enter program mode:
Step 1.
Stop the Drive (if it is running) by pressing the
STOP
RESET
key.
Step 2.
Press the
Mode
Enter
key until the PROGRAM LED turns on.
Parameter F-00 will be displayed. Use the
key or
key to
scroll through the parameter list. The error log follows parameter
F-49 and precedes parameter F-00 as shown in Figure 7.2.
Program Mode