Led descriptions – Rockwell Automation 1302 575v AC Drive - Canada Only User Manual
Page 53
7–3
Display and Keypad Operation
Publication 1302-5.0 — January, 1998
The keypad area contains eight LEDs that indicate either Drive status
or which Drive output value is displayed in monitor mode. Tables
7.B and 7.C describe the Drive status LEDs and monitor mode
LEDs, respectively.
Table 7.B - Drive Status LED Descriptions
LED
State
Description
Run
On
Off
The Drive is generating an output voltage and frequency.
The drive is not generating an output voltage and frequency.
!
ATTENTION: DO NOT use the RUN LED as an
indication that no line voltage is present in the Drive.
Verify there is no voltage present at the DC bus terminals
(+) and (–) before servicing the Drive. Failure to observe
this precaution could result in severe bodily injury or loss
of life.
Program
On
Off
The keypad and display are in program mode.
The keypad and display are in monitor mode.
Forward
On
Off
The requested motor rotation direction is forward.
The requested motor rotation direction is not forward.
Reverse
On
Off
The requested motor rotation direction is reverse.
The requested motor rotation direction is not reverse.
Remote
On
Off
The Drive is being controlled from the terminal strip.
The Drive is being controlled from the keypad.