Chapter

2

2–1

Publication 1302-5.0 — January, 1998

1302 AC Drive Description

This chapter describes the 1302 Drive and how to identify it based
on its model number. This chapter also provides power and
enclosure rating information.

The 1302 Drive has the following features:

On-board keypad and display providing:
Start/Stop/Reset control
Forward/Reverse (reverse-disable selectable)
Setpoint adjustment, Motor RPM, %load, or output voltage
display
Drive diagnostics

500 millisecond power dip ride-through

150% overload for one minute

0.5 to 240 Hz three-phase voltage output

NEMA 1 and NEMA 4/12 enclosures

A snubber resistor braking signal and a scaled voltage analog
output (0 to 10 VDC) which is proportional to:
Output frequency
Output amps
Output voltage
Selected reference

Quiet motor operation with high carrier frequency selection

Drive protection:
Overcurrent
Short circuit
Ground fault
Overvoltage
Undervoltage
Overtemperature

UL/CSA electronic overload that meets NEC/CEC requirements

User-selectable relay contact for indications of Drive running,
Drive faulted, or Drive at selected speed

User-selectable power-up start, auto-restart, and coast-to-rest or
ramp-to-rest stop functions

User-selectable local or remote operation

29 user–adjustable software parameters