7–8
Display and Keypad Operation
Publication 1302-5.0 — January, 1998
When the control source is the local keypad (F-00 = 0), the keypad is
used to control the Drive. This means that the Drive will respond to
START, STOP/RESET, and FORWARD/REVERSE commands only
from the keypad. The functions of the keypad keys are described in
section 7.2. Refer to the F-00 Control Source Select parameter
description in Chapter 8 for more information on selecting a Drive
control source.
Changing the Reference Using the Keypad
T
he speed reference can be increased or decreased using the
or
key when F-00 = 0 or 2. The display will show the internal
speed reference in hertz (Hz) while the keys are pressed. There will
be a slight delay before the display returns to the active monitor
mode.
Note that changing the drive’s internal speed reference using the
or
key when the Drive is under remote control will have no
operational effect on the Drive (unless F-00 = 2)
.