Rockwell Automation Motion Analyzer Software User Manual

Page 197

Advertising
background image

Rockwell Automation Publication MOTION-UM004B-EN-P - October 2012

197

Sizing Your System

Chapter 2

Enter the following parameters to further narrow the motor options and help you
decide which motor is best for your application.

Table 116 - Motor Series Selection Properties

Figure 147 - Compatible Motor Series

Table 117 - Motor Series Legend (refer to

Figure 147

)

Parameters

Description

Applications
Requirements
(label 1 in

Figure 146

)

Maximum Speed

Values are based on the information you entered in the previous tabs. These values cannot be
changed in this tab.

Continuous Torque

Peak Torque

Ambient
Temperature

Ambient temperature for the application environment.

Altitude

Altitude for the application environment.

Brake

From the Brake pull-down menu, choose YES or NO depending on your application.

Display Window
(label 2 in

Figure 146

)

Displays the available motor series. As application requirements are entered or motor series are selected, incompatible
motors are dimmed and crossed-out (boxed in red in

Figure 147

).

Symbol

Description

By hovering over this symbol, the particular motor series’ voltage ratings are displayed.

Indicates that the motor series supports the application.

Indicates that the motor series support for the application is marginal.

Indicates that the motor series is not recommended for the application.

Indicates that the motor series is incompatible with the application.

Advertising