Ipim module selection tab – Rockwell Automation Motion Analyzer Software User Manual

Page 42

Advertising
background image

42

Rockwell Automation Publication MOTION-UM004B-EN-P - October 2012

Chapter 1

Welcome to Motion Analyzer Software

Table 22 - Power Data Tab Descriptions

1.2.2.4.2.2. IPIM Module Selection Tab

Click the IPIM Module Selection tab to select an IPIM module.

Figure 27 - IPIM Selection Tab

Table 23 - IPIM Selection Tab Descriptions

Options

Description

Label 1 in

Figure 26

Name of the power rail and selected IPIM module slot is displayed here. Click the power rail
name label switches the view from IPIM view to Power Rail - Power Supply view.

IDM Axis view
(label 2 in

Figure 26

)

Summary of the all IDM units associated with the selected IPIM module along with the Axis
Motoring Bus Current and Axis Regenerating Bus Current values of each IDM unit.

Back to Power Rail
(label 3 in

Figure 26

)

Click to switch the view from IPIM view to Power Rail - Power Supply view.

Options

Description

Selection mode
(label 1 in

Figure 27

Automatic

Select Automatic for Motion Analyzer software to search for the best IPIM
module solution for the selected slot.

Manual

Select Manual to manually select the IPIM module.

Current
Selection

Displays the selected IPIM module catalog number.

Search

Search button is disabled because only one catalog number is available.

Utilizations
(label 2 in

Figure 27

)

IPIM

Arrows provide the means to scroll forward/backward to smaller/larger
IPIM module catalog numbers.

DC Bus Current
RMS Limit

Graphical representation of DC bus current rms limit for the selected IPIM
module.

DC Bus Current
Instantaneous
Limit

Graphical representation of DC bus current instantaneous limit for the
selected IPIM module.

Advertising