Understanding Your System Solution

Chapter 3

The Thermal tab displays the output of drive and motor thermal models that
reside in the drive firmware.

Figure 162 - Thermal Graph

Table 128 - Axis System Performance (label 2 in

Figure 155

)

Parameters

Description

Motor/Drive Capacity

Select the thermal curves you would like displayed on the graph.

Steady State/Single Cycle

Select whether to view thermal data for Steady State or for a Single Cycle.

Full/Auto Scale

Select whether to view the data on the Full Scale graph (y-axis values from zero to the
maximum value) or Auto Scale graph (y-axis values from the minimum value to the
maximum value).

RBM tab

This graph is available after a Resistive Brake Module (RBM) has been added to the System
BOM (bill of materials) in the

Axis Stop

tab. The graph displays the Velocity versus Time

data for the RBM module.

Power-Supply

This graph is available after a Power Supply Analysis has been performed on the system in
the

Power Supply/Accessories View

. This graph displays the Voltage and Current

Simulation data.