Understanding Your System Solution

Chapter 3

3.2.2.4.1.1.3. Compliance

Choosing Compliance enables the following additional fields, in addition to the
Rigid coupling fields.

Figure 173 - Compliance Coupling

Table 137 - Compliance Coupling Options (refer to

Figure 173

)

Figure 174 - Stiffness Calculator

Options

Description

Damping Ratio

Enter a system damping ratio. The damping ratio provides a means of expressing the level
of damping in a system relative to critical damping.

Stiffness

The Stiffness entry is useful when Natural Frequency is not known, but stiffness is.

Stiffness Calculator

Click Stiffness to launch the stiffness calculator and calculate stiffness from Shear Modulus,
diameter and length.

Natural Frequency

Simulates a resonance between load and motor (0 = infinitely stiff).