Analysis tab – Rockwell Automation Motion Analyzer Software User Manual

Page 33

Advertising
background image

Rockwell Automation Publication MOTION-UM004B-EN-P - October 2012

33

Welcome to Motion Analyzer Software

Chapter 1

1.2.2.4.1.4. Analysis Tab

Click Analysis to conduct detailed analysis of the drive module activity in terms
of bus volts and system current, along with the capability of simulating changes to
the system parameters.

Figure 25 - Analysis Tab Dialog Box

Table 19 - Analysis Tab Properties

If the time is increased, this error message often appears.

This time slice message may also appear as soon as you click Solution on the main
taskbar. In this case, clicking Yes or No still takes you to the Solution tab, but if
you click No, some pre-calculations are not performed.

This time slice message often appears if one of the motion cycles is a cam, which
often has very short time segments. In this case, click No to ignore the message.

Parameters

Description

Simulation Parameters
(refer to

Figure 25

)

Adjust these parameters to observe how changes to the parameters impact the bus voltage and current.

Zoom Window
(refer to

Figure 25

)

Time From/
Voltage From

Check these boxes to adjust the X- and Y-axis values for the plot.

Time Slice

The Time Slice variable sets the time interval for the Analysis display. Because the shunt switching action is
modeled during selection, this value needs to be very short to obtain an accurate shunt selection (0.1 ms, for
example). However, if the total cycle time is more than a few seconds, the calculation time may become excessive.
The time is equal to the longest axis cycle. In the case of a very long length of time, it is suggested that a longer time
slice be used for early checks, but a time slice of less 0.1 ms should be used for the final selection.

Advertising