Canon GM-1000 User Manual

Page 104

Advertising
background image

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

104

Command ID

26

Command

Name

Parameter Value Check

Data

Parameter ID

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation This command returns the parameter setting of Parameter ID.

Command ID

30

Command

Name

Program Coordinate System

Data

0: Z phase
1: Program Origin

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation For a raster scan, the center of the oscillation angle can be changed.

0: Z phase

Set the Z-phase position as the center. This setting is in the default after start up.

1: Program Origin

Set the current position as the center.
When setting the program origin, move once to the desired center and then specify the
position by this command.

Command ID

40

Command

Name

Monitor Output Selection A2 (A8)

Data

0: Head1 A phase signal
1: Head2 A phase signal
2: Corrected A phase signal
3: Deviation signal

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation The output signal of analog monitor output A2 (Axis 1) and A8 (Axis 2) can be selected.

When the controller starts, the 3: Position error has been selected.
(For details, see5.2. , “Analog Monitor Output Selecting ”)

Command ID

41

Command

Name

Monitor Output Selection A3 (A9)

Data

0: Current position signal
1: Velocity signal
2: Corrected encoder count
3: Encoder interpolation data

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation The output signal of analog monitor output A3 (Axis 1) and A9 (Axis 2) can be selected.

When the controller starts, the 1: Velocity has been selected.
(For details, see 5.2. , “Analog Monitor Output Selecting ”)

Advertising