Canon GM-1000 User Manual

Page 135

Advertising
background image

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

135

Usually, settings in the window do not need to be changed, however, need to change when

the connected COM port differs. When writing fails frequently, change the baud rate (default

value of 57600) to a smaller value and try again.

6. When Write Complete displays in the log display area, it is finished.

7. Shut down GCFlash. (It is necessary to completely shut down once.)

8. Turn off the GC-201 controller’s power.

9. Updating the DSP of Axis 2

With the GC-201 controller’s power turned off, set the jumper switches and DIP switches as

follows.

SW2 : 1-ON

JP1

: 2-3 Short

JP2

: 2-3 Short

10. Follow instructions 3 to 6.

11. Shut down GCFlash and turn off the GC-201 controller’s power.

12. With the GC-201 controller’s power turned off, return settings to the jumper switches and DIP

switches as follows.

JP1

1

2

3

JP2

1

2

3

SW2

1

2

OFF
ON

According to the controller settings, the default state of "2" of SW2 will differ. This is

regardless of a firmware update. Do not change from the default state.