High-speed serial communication motor drive timing, Command, 20us – Canon GM-1000 User Manual

Page 33

Advertising
background image

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

33

2.8.3.2. High-speed serial communication motor drive timing

The following diagram indicates actual motor drive signal output timing when the high-speed serial

communication position command is received.

COMMAND

XY-2 COMMAND
FRAME SYNC

DSP Sampling Clock

Output to MOTOR

10us

10us

CONTROL

5us

5us

20us

Target
Position1

Target
Position2

Target
Position3

Target
Position1

5us

COMMAND

XY-2 COMMAND
FRAME SYNC

DSP Sampling Clock

Output to MOTOR

10us

10us

CONTROL

5us

5us

20us

Target
Position1

Target
Position2

Target
Position3

Target
Position1

5us

Advertising