CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

27

(Target Position Data) DAT (AXIS1), DAT (AXIS 2)

It is possible to switch the length of data used as target position data from the DAT (AXIS1), DAT (AXIS

2) 20 bit (every 100 kHz) signals. Please set appropriately to match the signal specifications of the

scanner controller that outputs a high-speed serial communication signal, and other output equipment.

Note: The length of data input in the GC-201 is always 20 bit (every 100 kHz). The bits of the target

position data that get used and sent are switched from within 20 bit data.

When there is a big difference in the target position specified in the high-speed serial communication,

and the actual operation position, it is possible this parameter setting is incorrect. Please verify.

The data length of the target position data by the high-speed serial communication can be changed by

two following parameters.

(Target position data length)

Can be changed by 16 bit – 20 bit.

Parameter ID

DATA

67

16: 16bit Data *

17: 17bit Data

18: 18bit Data

19: 19bit Data

20: 20bit Data

(Data position)

The least significant bit position of the target position data of high-speed serial communication 20bit

data can be set by following parameter. The specified number of bits is shifted right, making the target

position data.

Parameter ID

DATA

68

0: 0bit position

1: 1bit position *

2: 2bit position

3: 3bit position

4: 4bit position

With the default settings at shipping, the setting is * (16 bit position data length, data least significant bit 1

bit position). This communication specification is compatible with XY2-100. When using the scanner

controller of XY2-100 specifications, please use this setting.

Advertising