Writing parameters to ROM is also possible with commands via RS-232C.

When writing parameters to ROM, a reply that definitely contains data will be sent by a controller.

The content of data is different by a parameter. (For details, see 9.2. “Parameter Details”)

(Note: Carry out writing parameters to ROM only after thoroughly verifying the content. Depending on

the changed values, the controller may not start normally.)

Parameter ROM Write send

E Axis No. P Parameter ID / Data Delimiter







E.g. LQ gain parameter ID = 6 Data = 4500

E1P006 / 4500 (LF)

(ASCII code: 0x45 0x31 0x50 0x30 0x30 0x36 0x2f 0x34 0x35 0x30 0x30 0x0a)

E 1 P 0 0 6 / 4 5 0 0 (LF)

Parameter ROM Write reply

E Axis No. P Parameter ID / Data Delimiter







E.g. LQ gain parameter ID = 6 Data = 4500

E1P006 / 4500 (LF)

(ASCII code: 0x45 0x31 0x50 0x30 0x30 0x36 0x2f 0x30 0x0a)

E 1 P 0 0 6 / 0 (LF)



Axis No.

1 or 2

Parameter ID
Decimal, 3-digit
(See 7.1 for details)

Parameter setting

Decimal

Parameter

Delimiter

LF or CR

Axis No.

1 or 2

Parameter ID
Decimal, 3-digit
(See 7.1 for details)

Parameter setting

successful / unsuccessful

0 or 1

Parameter

Delimiter

LF or CR