Command ID

42

Command

Name

Monitor Output Selection A4 (A10)

Data

0: Head1 B phase signal
1: Head2 B phase signal
2: Corrected B phase signal
3: Target position signal

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation The output signal of analog monitor output A4 (the Axis1) and A10 (the Axis2) can be

selected.
When the controller starts, the 3: Internal Target has been selected.
(For details, see5.2. , “Analog Monitor Output Selecting ”)

Command ID

43

Command

Name

Monitor Output Select Check

Data

0: A2 (A8) monitor
1: A3 (A9) monitor
2: A4 (A10) monitor

Return
Value

Selected monitor number

Explanation The number of the monitor signal that has been selected by command ID=40, 41, and 4

2 can be confirmed.
E.g. A1C040/0 Return Value = 3 (Monitor A2 when the deviation signal is selected.)

Command ID

44

Command

Name

Monitor Magnification Setting
A2 (A8)

Data

Magnification : N (×2

N

)

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation Magnification is specified by an exponent of the power-of-two.

E.g.

Data = -2 2

-2

= 0.25 times

Data = -1 2

-1

= 0.5 times

Data = 0 2

0

= 1 times

Data = 1 2

1

= 2 times

Data = 2 2

2

= 4 times

(See 5.2. , “Analog Monitor Output Selecting”)