Canon GM-1000 User Manual

Page 118

Advertising
background image

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

118

Parameter ID

26

Parameter

Name

Cycle Time of Raster Scan

Data

Scan Time (Unit: See Explanation.)

Return Value 0: Parameter setting successful

1: Parameter setting unsuccessful

Explanation

This command is used to set the raster scan time (operation by command).
The scan time is the set value × 10 μs.
E.g. For the interval of 100 ms, set 10000 (10000 × 10 μs = 100 ms).


Related
Command
/Parameter

Duty of Raster Scan (Parameter ID = 27)
Scan Angle of Raster Scan (Parameter ID = 28)
Interval Time of Raster Scan (Parameter ID = 30)
Start Position of Raster Scan (Parameter ID = 31)

Parameter ID

27

Parameter

Name

Duty of Raster Scan

Data

Raster scan duty ratio (Unit: %)

Return Value 0: Parameter setting successful

1: Parameter setting unsuccessful

Explanation

This parameter is used to set the duty ratio of raster scan (operation by command).
(See Explanation of Parameter ID = 26.)

Related
Command
/Parameter

Cycle Time of Raster Scan (Parameter ID = 26)
Scan Angle of Raster Scan (Parameter ID = 28)
Interval Time of Raster Scan (Parameter ID = 30)
Start Position of Raster Scan (Parameter ID = 31)

CW

CCW

Scan Angle 
(+)

0

Raster Scan Time

Scan Angle 
(-)

CW

CCW

Scan Angle 
(+)

0

Raster Scan Time

Scan Angle 
(-)