CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

90

• By pressing the SETUP button, operating conditions during FULL AUTO can be set. Usually default

parameter settings will operate correctly.

• Frequency

Frequency when measuring the frequency response

• GAIN

Max Change

Permissible change rate from the original gain setting value.

If this value is exceeded, the operation will be stopped with an error.

Target Range

Adjustment takes place so the margin of error between both axis is

lower than this value.

• Q

Fine Step

Amount of step adjustment for Q

Max Change

Permissible change rate from the original Q setting value.

If this value is exceeded, the operation will be stopped with an error.

Target Range

Adjustment takes place so the margin of error between both axis is

lower than this value.