CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

131

Priority: Low

Error

Hex

Monitor Item

Error Condition

Setting

Change

Possible

/Impossible

(Parameter)

System

status after

error

Digital

Output

Recovery Method

Clock lack

0x0008

High-speed serial communications
clock

The clock is no longer input

Impossible

Input the clock
normally. If input
normally it will return.

Format error

0x0040

Command format

An undefined command or parameter is
sent.

Impossible

Error output

only

(Axis1)

Connector

B1

Monitor

Board

D2


(Axis 2)

Connector

A3

Monitor

Board

D5

Error clearance

(C01)

Command data error

0x0080

Command data

Command data is illegal.
No data is given to a command requiring
data.
Data is given to a command requiring no
data.
Data outside the setting range is set.

Impossible

Parameter error

0x0100

Parameter value

A parameter value is beyond the setting
range.

Impossible

Status error

0x0200

Command description

A command not valid for the current status
is sent.

Impossible

Communication error

0x0400

Communication flag

Communication flag time-out occurs.

Impossible

Out-position error

0x2000

Encoder pulse count

The setting of P24 (Out-position Width) is
exceeded.

Possible

(P24)