CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

130

10.2. Errors

Priority: High

Error

Hex

Monitor Item

Error Condition

Setting

Change

Possible

/Impossible

(Parameter)

System

status after

error

Digital

Output

Recovery Method

Stroke over

0x0001

Encoder pulse count

The encoder count is outside the range set
by parameters P00 (CW Limit) and P01
(CCW Limit).

Possible

(P00, P01)

Error Output

Servo OFF

(Axis1)

Connector

A1

Monitor

Board

D1

(Axis2)

Connector

B2

Monitor

Board

D4

Soft reset

(C00)

+

Homing

(C02)

or

Power-off/on

Counter over

0x0002

Velocity (calculated from encoder
pulses)

The velocity exceeds the setting by P02
(Maximum Velocity).

Possible

(P02)

In-position overtime

0x0004

Encoder pulse count

The accumulated time based on the setting
of P03 (In-position Range) exceeds the
setting of P05 (In-position Overtime).

Possible

(P03, P05)

Driver overheat

0x0010

A/D value of thermistor at controller
output amplifier

The driver temperature exceeds the A/D
value corresponding to 70ºC. (Software
monitoring)

Impossible

Motor overheat

0x0020

A/D value of thermistor at motor
coil

The motor temperature exceeds the A/D
value corresponding to 70ºC. (Software
monitoring)

Impossible

Origin detection error 0x0800

Homing to the origin

Homing is not completed normally. Impossible

Encoder signal error

0x1000

Encoder signal level at homing to
origin

An encoder signal is abnormal.

Impossible

Servo off by hardware

0x4000

Output amplifier shutdown function
Thermistor (controller and motor)

The output amplifier is shut down.

Impossible

Current saturation

0x8000

Output

current

command

Current saturation (10A×P09 (Current
limit)) continues for a specified time or
longer.

Possible

(P09)