CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

98

Command ID

7

Command

Name

Control Mode Specification

Data

0: PI control
1: LQ control

Return

Value

0: Command execution successful
1: Command execution unsuccessful

Explanation LQ control is usually used.

Command ID

8

Command

Name

Movement Start

Data

0: Step movement start
6: Movement to the initial position of raster scan

Return

Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

Usual movement: After a target position is set, this command is executed to start step
movement.
Movement to the raster scan’s start position: After setting the raster scan condition
settings, this command is executed to move to the start position.

Related

Command

Step movement procedure

Command ID = 10: Target Value Setting Mode

Command ID = 20: Target Position Setting

Command ID = 8: Data = 0: Step Movement Start

Raster scan movement procedure

Parameter ID = 26: Raster Scan Interval

Setting

Parameter ID = 27: Raster Scan Duty Ratio

Setting

Parameter ID = 28: Raster Scan Oscillation Angle

Setting

Command ID = 8 Data = 6: Movement to the raster scan initial position

Command ID = 23 Data = 3: Raster Scan Start (Continuous)

Command ID = 23 Data = 0: Raster Scan Stop


Command ID

9

Command

Name

Forced Stop

Data

-

Return

Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

This command is used for a stop before the target position during movement by
Command ID = 8.

Related

Command

Command ID = 8 Data = 0: Movement Start