Safety functions – Canon GM-1000 User Manual

Page 129

Advertising
background image

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

129

10.

Safety Functions

This system has various safety functions to ensure safe use.

10.1. Safety Functions

The safety functions can be classified into hardware monitoring and software monitoring.

Hardware monitoring

・Power supply fuse

+24 V line (each axis)

+5 V line

・Output amplifier overheat

Temperature monitoring by thermistor (abut 80ºC)

・Motor overheat

Temperature monitoring by thermistor (abut 75ºC)

(If output amplifier or motor overheat is detected, the amplifier output is shut down.)

・Output amplifier IC

Shutdown function

Software monitoring

The controller status is always monitored by software and error notification is made if an abnormality

occurs.

Depending on the error type (priority), digital monitor I/O (2 bits) is used for this notification.

The details of an error can be checked by an RS-232C command.

See 10.2, “Errors” for the error details.

Note: The post-error system status and recovery method depend on the priority of the error.

See

10.2,

“Errors.”

Note: Temperature settings of the above hardware temperature monitoring and software

temperature

monitoring

differ.

Usually,

temperature monitoring of software operates first,

and it is set to carry out error input and servo off operations.