Canon GM-1000 User Manual

Page 106

Advertising
background image

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

106

Command ID

46

Command

Name

Monitor Magnification Setting
A3 (A9)

Data

Magnification : N (×2

N

)

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation Magnification is specified by an exponent of the power-of-two.

E.g.

Data = -2 2

-2

= 0.25 times

Data = -1 2

-1

= 0.5 times

Data = 0 2

0

= 1 times

Data = 1 2

1

= 2 times

Data = 2 2

2

= 4 times

(See 5.2. , “Analog Monitor Output Selecting”)

Related
Command

Command ID

47

Command

Name

Monitor Magnification Setting
A4 (A10)

Data

Magnification : N (×2

N

)

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation Magnification is specified by an exponent of the power-of-two.

E.g.

Data = -2 2

-2

= 0.25 times

Data = -1 2

-1

= 0.5 times

Data = 0 2

0

= 1 times

Data = 1 2

1

= 2 times

Data = 2 2

2

= 4 times

(See 5.2. , “Analog Monitor Output Selecting”)

Related
Command

Command ID

48

Command

Name

Monitor Magnification Check

Data

0: A2, A8 monitor magnification
1: A3, A9 monitor magnification
2: A4, A10 monitor magnification

Return
Value

Magnification : N (×2

N

)

Explanation The exponent of power-of-two.

(See 5.2. , “Analog Monitor Output Selecting”)







Advertising