5.3. Digital Input-Output Function

The controller has a digital input-output function for checking the status of the controller.

Pin

No.

I/O Signal

Description Logic

Explanation

A1

Output

Axis 1 Error 1 (Priority high)

High:

Error If an error occurs, the

corresponding error signal is
output.
According to the priority of the

error, Error 1 or 2 is output.

See 9-2, “Errors.”

B1

Output

Axis 1 Error 2 (Priority low)

High: Error

B2

Output

Axis 2 Error 1 (Priority high)

High: Error

A3

Output

Axis 2 Error 2 (Priority low)

High: Error

A2

Output

Axis 1 servo interrupt period

Edge

Output is timed according to
an internal controller servo
interrupt..

B3

Output

Axis 2 servo interrupt period

Edge

In addition, the following digital I/O is prepared as an operation setting of the controller.

Pin

No.

I/O Signal

Description

Logic

Explanation

A5

Input External Sampling Signal

↑: INT

generation

Input when an external signal is

used for servo sampling clock.

(Do not use it usually.)

B5

Input External Trigger Signal

High: FG_ON

See 6-2, “Operation that

synchronizes with external

trigger signal input (raster scan)

A6

Input Start up mode switching

See 6-1, “Setting Controller Start

Up Mode”