Other - Operation Setting

6.1. Setting Controller Start Up Mode

Clock selection

With the default settings at shipping, a parameter is set to start up the controller in RS-232C

communication command input mode (internal clock). When assembling the device, however, the

mode can be switched for start up with an external clock (high-speed serial communication). For this

switching, the following parameter is set:

Parameter ID

Data

64

Bit 1 0: RS-232C communication command input
1: High-speed serial communication

P64 = 1: Start up with internal clock

P64 = 3: Start up by high-speed serial communication

(Bit 0 of P64 is used to enable or disable encoder correction when homing to the origin; it is usually set

to 1. For details, see 9.2. , “Parameter Details”)

Start up mode

Power-on usually executes the following automatically:

Reading parameters from EEPROM

Starting homing and servo control

If there is a problem with the parameters read from EEPROM or if oscillation occurs when homing and

servo control are executed automatically, the start up mode can be changed.

For this switching, the switches (SW1 and SW2) on the controller board and the logic of the digital I/O

terminal (A6) are combined.