Writing parameters into rom – Canon GM-1000 User Manual

Page 127

Advertising
background image

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

127

9.4. Writing Parameters into ROM

All parameters are written in the controller ROM. At Start up, the parameters are automatically read

and set in the controller.

If parameters are modified, they should be written into ROM for start up with the same settings at the

next power-on. Write modified parameters into ROM as follows:

Control Software




















Select the All Parameter tab. ①

Select an axis for parameter settings. ②

The current parameter values are displayed. ③

Press the Save to EEPROM button. ④

Input password “Canon”

“Saving to EEPROM” is displayed. ⑤

Note: Some parameter settings may disable normal start up next time.

If this problem occurs, change the start up mode for no automatic homing to the origin and

check the set values. (See 6.1, “Setting Controller Start Up Mode.”)

Advertising
This manual is related to the following products: