2.8.3.1. Origin Offset

It is possible to change the origin position of high-speed serial communications.

Parameter ID

Data

15

High-speed serial communication

offset

Unit: pulse

Unit is pulse.

High-speed serial communication offset is not influenced by the parameter ID = 13 high-speed serial

communication conversion gain setting.

E.g.

When parameter ID = 15 setting 2276 pulse (=0.1°) is set, regardless of the parameter ID = 13 setting, it

will always operate with a 0.1° (CW direction) offset.

Note) Current position output data of Next heading 2.8.4. is actual motor encoder position data.

Current position output data

= High speed serial communication command position + High speed serial communication offset

So, Current position data is not equal to High speed serial communication command position that

you specify.