Canon GM-1000 User Manual

Page 37

Advertising
background image

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

37

2.8.5. RS-232C Communication Command Input and High-Speed Communication

Switching

A position command input can be switched with a RS-232C communication command.

Command ID

Data

23

0: RS-232C command communication

7: High-speed serial communication








Note: In the case of two axis control, it is necessary to execute this command for each axis.

It is possible to receive input of RS-232C communication commands even when switching to

high-speed serial communication. However, as position commands give priority to the input of

high-speed serial communication, operation commands such as RS-232C communication command

step movement, and raster scans will be ignored.

Command ID = 23 Data 7

A1C023/7

A2C023/7

Command ID = 23 Data 0

A1C023/0

A2C023/0

High-speed serial

communication

RS-232C command

communication

*Command also sent to Axis 2

*Command also sent to Axis 2

Advertising