4.4. Position Command Input by High-speed Serial Communication

In order to carry out a vector scan, target position data is given to the controller by high-speed serial

communication, and the data is updated as required.

It is possible to change the mode of the controller to the mode of receiving target position data by

high-speed serial communication. For changing the mode, it is necessary to enter high-speed serial

communication signals into the controller in advance.

Control Software

Switch HiSpeed Serial to Start. ①

This switching makes the controller follow target position data by high-speed serial communication.

Switch HiSpeed Serial to OFF. ②

Input of the MOVE command is awaited.

RS-232C commands

Switch to high-speed serial communication (Command ID = 23 Data = 7)

Return to internal clock operation (Command ID = 23 Data = 0)