CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

66

5.2. Analog Monitor Output Selecting

The analog monitor output can be switched to monitor various operation and signal statuses.

This switching can be executed from [Control Software] or [RS-232C command send].

Output contents

Terminal

Monitor Board

Signal Name

Power-on

Selection

Signal Description

Signal Level (At

Power-on)

2 (Axis 1)
6 (Axis 2)

A2 (Axis 1)
A6 (Axis 2)

Phase A of Encoder Head 1

Phase A of Encoder Head 2

Phase A of encoder after synthesis

*

Positional deviation signal

1.5 mV / pulse

3 (Axis 1)
7 (Axis 2)

A3 (Axis 1)
A7 (Axis 2)

Position

0.091 mV / pulse

*

Velocity

0.091 mV / pulse / 10

Coarse

angle

Fine

angle

4 (Axis 1)
8 (Axis 2)

A4 (Axis 1)
A8 (Axis 2)

Phase B of Encoder Head 1

Phase B of Encoder Head 2

Phase B of encoder after synthesis

*

Target position

0.091 mV / pulse

The signal level differs between signals. The output magnification can be switched individually.